PostPosted: Wed Jun 10, 2015 2:49 pm    Post subject: Roof soffit, weak link? Reply with quote

So my first round of framing is done on my new build (pictures will come, I swear). My contractor and I were laying some things out/ordering materials when I asked him about the gaps between the rafters of our roof. He explained that they're to let fresh air in/moisture out, but they'll be covered by soffit material on the outside.

My wonder was:

If I plug those gaps with wood will it cause serious moisture problems (I'm already going to be pumping fresh air in to the control room and live room since they're sealed)?

Will soffit material be enough to contain the sound of the outer layer of my room-within-a-room design?
_________________
Mo' mics mo' problems.

http://www.facebook.com/pages/The-Furnace-Room/292960857423152
Back to top
View user's profile Send private message Visit poster's website
floid
re-cappin' neve


Joined: 03 Jan 2006
Posts: 741
Location: in exile

PostPosted: Wed Jun 10, 2015 5:21 pm    Post subject: Re: Roof soffit, weak link? Reply with quote

You need venting. Moisture leads to mold. This is for the attic space, not the room itself. The soffit vent pulls air in at the eave, which vents out at a gable or ridge vent. Plywood soffit with vent holes is probably going to contain sound better than vinyl soffit - these are the two most popular options. If you have attic space, it might be possible to design a more convoluted system that satisfies the same requirements.
_________________
Village Idiot.
Back to top
View user's profile Send private message
norton
buyin' a studio


Joined: 07 Aug 2003
Posts: 839
Location: minneapolis

PostPosted: Thu Jun 11, 2015 8:42 am    Post subject: Re: Roof soffit, weak link? Reply with quote

Shouldn't be a problem.

You could investigate going to a hot roof model. This is where the insulation envelope goes all the way to the roofline itself. The hot roof is a non vented design, but isn't accepted as "code" everywhere.

Your inner envelope (room/room) should be fine.
Back to top
View user's profile Send private message
losthighway
carpal tunnel


Joined: 14 Apr 2008
Posts: 1584

PostPosted: Thu Jun 11, 2015 10:34 am    Post subject: Re: Roof soffit, weak link? Reply with quote

Sorry, Norton, are you saying that a typical venting soffit scenario shouldn't be a problem for sound transmission, or that blocking off the rafters shouldn't be a problem for moisture?
_________________
Mo' mics mo' problems.

http://www.facebook.com/pages/The-Furnace-Room/292960857423152
Back to top
View user's profile Send private message Visit poster's website
norton
buyin' a studio


Joined: 07 Aug 2003
Posts: 839
Location: minneapolis

PostPosted: Fri Jun 12, 2015 11:55 am    Post subject: Re: Roof soffit, weak link? Reply with quote

Typical Vented roof scenario shouldn't be much of a problem as far as sound transmission goes. Your room within a room and attic insulation should cover any real world sound transmission concerns.

Taking the roof venting of the equation could pose problems.....unless that roof insulation system is redesigned to be a "hot roof". Which basically means that the insulation between the outside and your ceiling is sufficient enough to never allow the heat in your house to reach the shingles (outer roofing) and cause melting/moisture buildup. Generally this requires a blown in foam insulation type to create that perfect seal/moisture barrier.

If you've already got a vented roof system set up and have any budgetary concerns at all, I'd say you'll be A.O.K.!
Back to top
View user's profile Send private message
losthighway
carpal tunnel


Joined: 14 Apr 2008
Posts: 1584

PostPosted: Sun Jun 14, 2015 1:53 pm    Post subject: Re: Roof soffit, weak link? Reply with quote

Cool. You two form a consensus with my contractor. Traditional soffits it is!
_________________
Mo' mics mo' problems.

http://www.facebook.com/pages/The-Furnace-Room/292960857423152
Back to top
View user's profile Send private message Visit poster's website
Display posts from previous:   
Post new topic   Reply to topic   printer-friendly view    Tape Op Message Board Forum Index -> Making A Space All times are GMT - 4 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum